ATEX Zone to NEC Class/Division Hazardous Area Converter
Convert between ATEX / IECEx Zones (0, 1, 2, 20, 21, 22) and NEC Class I / II Divisions (Div 1, Div 2) with gas/dust group cross-reference, protection methods, and certification checks.
Calculation inputs and results
ATEX / IECEx Zone vs. NEC Class & Division Reference Table
Use this static cross-reference to align international EPC lighting specifications between IEC 60079 (ATEX / IECEx) and NFPA 70 (NEC Articles 500–506). For deeper engineering context, see our guides on Class I Division 1 vs. Division 2 lighting, NEC vs. IEC gas groups, and using ATEX/IECEx equipment in the USA (AEx marking).
| Hazard Presence | ATEX / IECEx Zone | ATEX Category / EPL | NEC Class & Division | Typical LED Protection Methods |
|---|---|---|---|---|
| Continuous explosive gas (>1000 h/yr) | Zone 0 | Category 1G / Ga | Class I, Division 1 | Ex ia (Intrinsically safe) |
| Likely explosive gas (10–1000 h/yr) | Zone 1 | Category 2G / Gb | Class I, Division 1 | Ex db, Ex eb, Ex mb, Ex pxb |
| Abnormal / brief gas (<10 h/yr) | Zone 2 | Category 3G / Gc | Class I, Division 2 | Ex ec, Ex nR, Ex dc, Ex ic |
| Continuous combustible dust | Zone 20 | Category 1D / Da | Class II, Division 1 | Ex ia, Ex ta |
| Likely combustible dust | Zone 21 | Category 2D / Db | Class II, Division 1 | Ex tb, Ex mb, Ex pxb |
| Abnormal / brief combustible dust | Zone 22 | Category 3D / Dc | Class II, Division 2 | Ex tc, Ex ic |
Featured Certified Explosion-Proof Luminaires & Categories