Emergency Lighting Power Supplies

Match the backup source to the light.

Compare external emergency power units by supported load, output arrangement and duration. Confirm compatibility with the exact luminaire and its electrical circuit.

Developed and manufactured by TORMIN.
Wenzhou, China · Since 2003.

TORMIN ZLQ3140
ZLQ3140

Find the right configuration.

Selected series for different installation requirements.

Browse the full category
TORMIN ZLQ3140

ZLQ3140

External emergency power box

Input voltage
100–240 VAC
Emergency output
5–25 W by configuration
Ingress protection
IP66
View specifications
TORMIN BXP02

BXP02

A/B variant emergency power family

Input voltage
100–240 VAC
Emergency power options
5 / 10 / 15 / 25 W by variant
Emergency duration
≥90 / ≥180 min by variant
View specifications
TORMIN BXP01

BXP01

Load / duration-based emergency unit

Input voltage
90–264 VAC
Supported load options
10 / 20 / 30 W
Emergency duration
10 W: >140 min; 20 W: >70 min; 30 W: >45 min
View specifications

Values are model- and configuration-specific. Confirm the selected variant and its complete technical documentation before ordering.

Compare the starting points.

Key differences to guide your enquiry. Open each product for its full specification.

SeriesSelection focusKey specificationConfiguration detailYour enquiry
ZLQ3140External emergency power boxInput voltage100–240 VACEmergency output5–25 W by configuration
BXP02A/B variant emergency power familyInput voltage100–240 VACEmergency power options5 / 10 / 15 / 25 W by variant
BXP01Load / duration-based emergency unitInput voltage90–264 VACSupported load options10 / 20 / 30 W
ZLQ3140External emergency power box
Input voltage
100–240 VAC
Emergency output
5–25 W by configuration
Ingress protection
IP66
BXP02A/B variant emergency power family
Input voltage
100–240 VAC
Emergency power options
5 / 10 / 15 / 25 W by variant
Emergency duration
≥90 / ≥180 min by variant
BXP01Load / duration-based emergency unit
Input voltage
90–264 VAC
Supported load options
10 / 20 / 30 W
Emergency duration
10 W: >140 min; 20 W: >70 min; 30 W: >45 min

Family ranges cover multiple versions; not every combination is available. Values shown retain the configuration qualifiers in the product documentation.

Selection considerations

An emergency power unit must be reviewed with the connected luminaire and driver. ZLQ3140 lists emergency output configurations from 5 to 25 W, BXP02 separates power and duration by variant, and BXP01 lists different durations for 10, 20 and 30 W loads. Those duty points should remain paired: a duration quoted at one load cannot be applied to another. Provide the exact luminaire, normal load, input supply and output-voltage requirements before choosing a unit. Include the wiring arrangement, mounting location and environmental conditions in the enquiry. Where hazardous-area requirements apply, verify the complete proposed arrangement and its documentation instead of assuming that a separate power box establishes compatibility.

Start with your application.

Compare external emergency power units by supported load, output arrangement and duration. Confirm compatibility with the exact luminaire and its electrical circuit.

Discuss your requirements

Identify the connected luminaire

Provide the exact light source, driver and normal load details.

Set the emergency output

Specify the required output and duration as a matched duty point.

Check the electrical interface

Confirm input supply, output voltage range and wiring arrangement.

Verify installation compatibility

Review mounting, environment and any hazardous-area requirements for the complete arrangement.

TORMIN lighting assembly workshop
Lighting assembly
Laboratory evaluation equipment at TORMIN
Laboratory evaluation

Review the model.
Check the documents.

Use the exact model reference to bring the product data and your installation requirements together.

Open PDF

Available documents and approval scope vary by model and version.

A few practical questions.

Details that help move your selection forward.

Can any power box be connected to any luminaire?

No. Light-source voltage, driver arrangement, load and wiring must be compatible with the selected emergency unit.

Does a longer duration apply at every load?

No. BXP01 lists different duration points for 10 W, 20 W and 30 W loads. Check the matched configuration.

Are all units in this category approved for classified areas?

Do not infer approval from the category location. Request the exact unit and luminaire documentation and verify the complete installation.

Let’s define your requirements.

Provide the exact light source, driver and normal load details. Include a model reference if you have one.

Already have a specification?

Include the required configuration, quantity and supporting document requirements in your message.

Request a Quote

Fields marked * are required.

We use your details to respond to this enquiry. Read our Privacy Policy.

Tell us what you need.

Fields marked * are required.

Your details will be used to respond to this enquiry.