
BC5401
Twin-tube lighting
A two-tube fixture with wiring terminals at both ends and several catalogue mounting arrangements.
- Power
- 2×10 / 2×20 / 2×25 W
- Supply
- 90–264 VAC
- Protection
- IP66
Light the route.
Keep the work in view.
Compare TORMIN explosion proof LED linear and twin-tube lights for walkways, platforms and equipment access. Check fixture length, supply, mounting and the exact model documents before requesting a quotation.
Developed and manufactured by TORMIN.
Wenzhou, China · Since 2003.

Four series. Different formats, supplies and protection scopes.

Twin-tube lighting
A two-tube fixture with wiring terminals at both ends and several catalogue mounting arrangements.

Zone 1 / 2 catalogue scope
A diffused linear fixture with an independent wiring box and bracket, wall, guardrail and flange mounting options.

Zone 2 catalogue scope
A linear series with a distinct protection scope. Review the exact model separately from the BC5402A.

Configurable light sources
Compare light-source wattage and quantity together to define the required BC5407 configuration.
* BC5402A and BC5402B 80 W versions use 186–264 VAC. Other listed power options use the supply shown above. BC5401 ratings are per tube; each fixture uses two tubes.
Compare the essentials, then open a series for its complete configuration details.
| Series | Power options | Input voltage | Selection focus | Your enquiry |
|---|---|---|---|---|
| BC5401 | 2×10 / 2×20 / 2×25 W | 90–264 VAC | Two-tube configuration | |
| BC5402A | 30 / 40 / 60 / 80 W | 108–264 VAC* | Gas Zones 1 / 2¹ | |
| BC5402B | 20 / 40 / 60 / 80 W | 90–264 VAC* | Gas Zone 2¹ | |
| BC5407 | 9–81 W by configuration | 90–264 VAC | 1 / 2 / 3 light sources |
¹ Gas-zone references are catalogue scope, not a substitute for checking the exact model marking, certification and site conditions. BC5402B emergency configurations are a separate selection.
Linear lighting selection depends on available fixture length, fixing points and the route or platform being illuminated. BC5401 uses two tubes, so its 10, 20 or 25 W per-tube ratings must be read as a complete two-tube configuration. BC5402A and BC5402B have different catalogue protection scopes and should not be treated as interchangeable fixtures. Their 80 W versions also use a different supply range from the lower-power options shown here. For BC5407, specify both light-source wattage and quantity. Include cable-entry positions, circuit arrangement and maintenance access with the layout, then verify the exact model marking and documentation. Specify emergency operation separately whenever battery-backed lighting is required.
Send the available fixture length, fixing positions, supply and area-classification requirements. The oil and gas lighting RFQ guide shows how to organize these inputs by installation location.
Discuss your requirementsZone or classification, gas or dust group, temperature class and required certification.
Available length, fixing points, mounting height and the walkway, platform or work area to be lit.
Available voltage, cable entries, circuit arrangement and any requirement for connecting multiple fixtures.
Ambient temperature, corrosion exposure, maintenance access and any separately specified emergency-lighting requirement.
Review each installation against its own environmental and hazardous-area requirements.

Review visibility along routes, fixing positions and access for maintenance.

Match the fixture, cable entries and mounting arrangement to the site conditions.
Application imagery from the TORMIN product catalogue; shown as installation references.


Bring the selected model and installation requirements together with the right technical documents. Our manufacturing and laboratory teams support the product evaluation process.
Certification scope and available documents vary by model and version.
Details that help move your selection forward.
No. The catalogue lists different protection scopes: BC5402A for gas Zones 1 and 2, and BC5402B for gas Zone 2. Confirm the exact model marking, certification and installation conditions; appearance and IP66 alone do not establish suitability.
No. BC5402A 30–60 W versions list 108–264 VAC and BC5402B 20–60 W versions list 90–264 VAC. Their 80 W versions list 186–264 VAC. Confirm the supply for the selected configuration.
BC5401 uses two T8 LED tubes, with each tube rated at 10, 20 or 25 W. BC5407 combines light-source wattage and quantity. Compare the complete fixture configuration rather than treating a per-source rating as total input power.
Do not assume it is included in a standard fixture. A separate BC5402B emergency configuration is documented; specify the emergency requirement and request its dedicated datasheet and applicable model documents.
Share the classified area, fixture length, supply and quantity. We’ll help you review the series and prepare the information needed for a quotation.
Include the model, supply voltage and required documentation in your message.