Adjustable sight-glass mounting
The bracket allows the lamp position and distance to be adjusted for the reactor sight-glass installation.
HAZARDOUS AREA LIGHTING
BC9502 is designed to illuminate reactor sight glasses so that operators can observe the process inside. The mounting bracket provides adjustment between the lamp and the viewing area.
The bracket allows the lamp position and distance to be adjusted for the reactor sight-glass installation.
The catalogue specifies Ra90 standard colour rendering for viewing the reaction within the vessel.
The source describes external switching, immediate switching and a delayed-off option; the applicable ordering reference must be confirmed.
The outer surface avoids grooves where liquid could collect, and the housing uses treated aluminium with 304 stainless steel fittings.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Switch mode | Mounting type (printed) | Select |
|---|---|---|---|---|---|
| BC9502S-L10 | 90–264 VAC | 10 W | External switch | Vertical installation | |
| BC9502BS-L10 | 90–264 VAC | 10 W | Conventional switch | Vertical installation | |
| BC9502BS-L10 | 90–264 VAC | 10 W | Delay switch | Vertical installation | |
| BC9502S-L20 | 90–264 VAC | 20 W | External switch | Vertical installation | |
| BC9502BS-L20 | 90–264 VAC | 20 W | Conventional switch | Vertical installation | |
| BC9502BS-L20 | 90–264 VAC | 20 W | Delay switch | Vertical installation | |
| BC9502Z-L10 | 90–264 VAC | 10 W | External switch | Vertical installation | |
| BC9502AZ-L10 | 90–264 VAC | 10 W | Conventional switch | Vertical installation | |
| BC9502BZ-L10 | 90–264 VAC | 10 W | Delay switch | Vertical installation | |
| BC9502Z-L20 | 90–264 VAC | 20 W | External switch | Vertical installation | |
| BC9502AZ-L20 | 90–264 VAC | 20 W | Conventional switch | Vertical installation | |
| BC9502BZ-L20 | 90–264 VAC | 20 W | Delay switch | Vertical installation | |
| BC9502S-L10 | 9–42 VAC /12–48 VDC | 10 W | External switch | Vertical installation | |
| BC9502AS-L10 | 9–42 VAC /12–48 VDC | 10 W | Conventional switch | Vertical installation | |
| BC9502BS-L10 | 9–42 VAC /12–48 VDC | 10 W | Delay switch | Vertical installation | |
| BC9502S-L20 | 9–42 VAC /12–48 VDC | 20 W | External switch | Vertical installation | |
| BC9502AS-L20 | 9–42 VAC /12–48 VDC | 20 W | Conventional switch | Vertical installation | |
| BC9502BS-L20 | 9–42 VAC /12–48 VDC | 20 W | Delay switch | Vertical installation | |
| BC9502Z-L10 | 9–42 VAC /12–48 VDC | 10 W | External switch | Vertical installation | |
| BC9502AZ-L10 | 9–42 VAC /12–48 VDC | 10 W | Conventional switch | Vertical installation | |
| BC9502BZ-L10 | 9–42 VAC /12–48 VDC | 10 W | Delay switch | Vertical installation | |
| BC9502Z-L20 | 9–42 VAC /12–48 VDC | 20 W | External switch | Vertical installation | |
| BC9502AZ-L20 | 9–42 VAC /12–48 VDC | 20 W | Conventional switch | Vertical installation | |
| BC9502BZ-L20 | 9–42 VAC /12–48 VDC | 20 W | Delay switch | Vertical installation |
| Input voltage (V) | 90~264VAC; 9~42VAC/12~48VDC(low voltage) |
|---|---|
| Rated frequency | 50Hz/60Hz |
| Light source | LED |
| CCT | 5700K(4000K/ 5000K optional) |
| CRI (Ra) | 90(70/ 80 optional) |
| Life time | 50,000hrs |
| Size | Φ105×144mm |
| Printed Ex marking | Ex db eb IIC T6 Gb; Ex tb IIIC T80°C Db |
| Ambient options printed in catalogue | −40 to +40 °C; exact variant and temperature class to be confirmed |
| Catalogue application areas | Gas Zones 1 and 2; dust Zones 21 and 22. Confirm the applicable model marking and installation conditions. |
| Cable entry | G1/2'' |
|---|---|
| Net weight | 1.3kg |
| Ingress protection | IP66 |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Reference | Supply | Mounting type (printed) | Rated power | Switch mode |
|---|---|---|---|---|
| BC9502S-L10 | 90–264 VAC | Vertical installation | 10W | External switch |
| BC9502BS-L10 | 90–264 VAC | Vertical installation | 10W | Conventional switch |
| BC9502BS-L10 | 90–264 VAC | Vertical installation | 10W | Delay switch |
| BC9502S-L20 | 90–264 VAC | Vertical installation | 20W | External switch |
| BC9502BS-L20 | 90–264 VAC | Vertical installation | 20W | Conventional switch |
| BC9502BS-L20 | 90–264 VAC | Vertical installation | 20W | Delay switch |
| BC9502Z-L10 | 90–264 VAC | Vertical installation | 10W | External switch |
| BC9502AZ-L10 | 90–264 VAC | Vertical installation | 10W | Conventional switch |
| BC9502BZ-L10 | 90–264 VAC | Vertical installation | 10W | Delay switch |
| BC9502Z-L20 | 90–264 VAC | Vertical installation | 20W | External switch |
| BC9502AZ-L20 | 90–264 VAC | Vertical installation | 20W | Conventional switch |
| BC9502BZ-L20 | 90–264 VAC | Vertical installation | 20W | Delay switch |
| BC9502S-L10 | 9–42 VAC /12–48 VDC | Vertical installation | 10W | External switch |
| BC9502AS-L10 | 9–42 VAC /12–48 VDC | Vertical installation | 10W | Conventional switch |
| BC9502BS-L10 | 9–42 VAC /12–48 VDC | Vertical installation | 10W | Delay switch |
| BC9502S-L20 | 9–42 VAC /12–48 VDC | Vertical installation | 20W | External switch |
| BC9502AS-L20 | 9–42 VAC /12–48 VDC | Vertical installation | 20W | Conventional switch |
| BC9502BS-L20 | 9–42 VAC /12–48 VDC | Vertical installation | 20W | Delay switch |
| BC9502Z-L10 | 9–42 VAC /12–48 VDC | Vertical installation | 10W | External switch |
| BC9502AZ-L10 | 9–42 VAC /12–48 VDC | Vertical installation | 10W | Conventional switch |
| BC9502BZ-L10 | 9–42 VAC /12–48 VDC | Vertical installation | 10W | Delay switch |
| BC9502Z-L20 | 9–42 VAC /12–48 VDC | Vertical installation | 20W | External switch |
| BC9502AZ-L20 | 9–42 VAC /12–48 VDC | Vertical installation | 20W | Conventional switch |
| BC9502BZ-L20 | 9–42 VAC /12–48 VDC | Vertical installation | 20W | Delay switch |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

Original catalogue extract · 2 pages · PDF · 167 KB
View documentOriginal catalogue pages 69, 70