Three rated currents
The selection table lists 10 A, 16 A and 20 A references.
EXPLOSION PROOF ELECTRICAL EQUIPMENT
BZM provides lighting-circuit switching in an aluminium-alloy enclosure. The catalogue lists current ratings and contact arrangements together for selecting the required switch.
The selection table lists 10 A, 16 A and 20 A references.
Monopolar, bipolar and dual-control versions have separate catalogue codes and contact diagrams.
G¾″, M25 × 1.5 and NPT ¾″ entry threads are listed for the enclosure.
The dimension drawing provides the enclosure outline and fixing arrangement for installation planning.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Rated current | Contact type | Select |
|---|---|---|---|
| BZM 10/A | 10 A | Monopolar | |
| BZM 16/A | 16 A | Monopolar | |
| BZM 20/A | 20 A | Monopolar | |
| BZM 10/B | 10 A | Bipolar | |
| BZM 16/B | 16 A | Bipolar | |
| BZM 20/B | 20 A | Bipolar | |
| BZM 10/C | 10 A | Dual control | |
| BZM 16/C | 16 A | Dual control | |
| BZM 20/C | 20 A | Dual control |
| Rated voltage | 220 / 230 / 250 V |
|---|---|
| Rated frequency | 50 Hz |
| Rated current (A) | 10 / 16 / 20 |
| Printed gas / dust marking | Ex db IIC T6 Gb / Ex tb IIIC T80 °C Db |
| Reference standards | EN IEC 60079-0; EN 60079-1, -31; IEC 60079-0, -1, -31; GB/T 3836.1, .2 |
| Catalogue application areas | Gas Zones 1 and 2, groups IIA / IIB / IIC; dust Zones 21 and 22, groups IIIA / IIIB / IIIC |
| Ingress protection | IP66 |
|---|---|
| Housing material | Aluminium alloy |
| Cable-entry thread | G¾″ / M25 × 1.5 / NPT ¾″ |
| Suitable cable diameter | Ø10–14 mm |
| Catalogue ambient-temperature options | −40 to +55 °C |
| Relative humidity | ≤95% at 25 °C |
| ATEX certificate: | IMQ 25 ATEX 004 X Archived copy on this site; confirm current status before specification. |
|---|---|
| IECEx certificate: | IECEx CQM 24.0056X Archived copy on this site; confirm current status before specification. |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Printed reference | Rated current (A) | Contact arrangement |
|---|---|---|
| BZM 10/A | 10 | Monopolar |
| BZM 16/A | 16 | Monopolar |
| BZM 20/A | 20 | Monopolar |
| BZM 10/B | 10 | Bipolar |
| BZM 16/B | 16 | Bipolar |
| BZM 20/B | 20 | Bipolar |
| BZM 10/C | 10 | Dual control |
| BZM 16/C | 16 | Dual control |
| BZM 20/C | 20 | Dual control |
| Code / reference | Meaning |
|---|---|
| A | Monopolar (A may be omitted) |
| B | Bipolar |
| C | Dual control |
| BZM-10 | 10 A monopolar example |
| BZM-16/B | 16 A bipolar example |