Two operating arrangements
The A/B model choice determines whether the fixture provides normal lighting as well as emergency lighting.
HAZARDOUS AREA LIGHTING
BC9101A and BC9101B provide two emergency-lighting arrangements. Type A combines normal lighting with emergency operation, while Type B is intended for emergency illumination.
The A/B model choice determines whether the fixture provides normal lighting as well as emergency lighting.
The adjustable bracket allows the lighting direction to be set and locked.
The housing uses a protective surface treatment with 304 stainless steel exposed fasteners.
Emergency wattage, output and duration are listed together for each catalogue reference.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Emergency power | Emergency duration | Operation | Catalogue mounting height (m) | Emergency luminous flux | Select |
|---|---|---|---|---|---|---|---|---|
| BC9101A-L25-15 | 90–264 VAC | 25 W | 15 W | 120 min | Maintained emergency | 2–5 m | 1,800 lm | |
| BC9101A-L40-15 | 90–264 VAC | 40 W | 15 W | 120 min | Maintained emergency | 2–5 m | 1,800 lm | |
| BC9101A-L60-15 | 90–264 VAC | 60 W | 15 W | 120 min | Maintained emergency | 3–8 m | 1,800 lm | |
| BC9101A-L25-25 | 90–264 VAC | 25 W | 25 W | 70 min | Maintained emergency | 2–5 m | 3,000 lm | |
| BC9101A-L40-25 | 90–264 VAC | 40 W | 25 W | 70 min | Maintained emergency | 2–5 m | 3,000 lm | |
| BC9101A-L60-25 | 90–264 VAC | 60 W | 25 W | 70 min | Maintained emergency | 3–8 m | 3,000 lm | |
| BC9101B-L15 | 90–264 VAC | — | 15 W | 120 min | Auto emergency | 2–5 m | 1,800 lm | |
| BC9101B-L25 | 90–264 VAC | — | 25 W | 70 min | Auto emergency | 2–5 m | 3,000 lm |
| Input voltage (V) | 90~264VAC |
|---|---|
| Life time (h) | 100,000 |
| Rated frequency | 50Hz / 60Hz |
| Time of charging (h) | >6 |
| Rated capacity | 2.6Ah/14.8V |
| Printed Ex marking | Ex db IIB T6 Gb; Ex tD IIIC T80°C Db |
| Catalogue application areas | Gas Zones 1 and 2; dust Zones 21 and 22. Confirm the applicable model marking and installation conditions. |
| Cable entry | G3/4" |
|---|---|
| Leading-in cable diameter | φ9mm~φ14mm |
| Dimension (mm) | 370×326×88 |
| Net weight (kg) | 9 |
| Ingress protection | IP66 |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Catalogue reference | Input voltage | Normal / rated power (W) | Emergency power (W) | Emergency output (lm) | Emergency duration (min) |
|---|---|---|---|---|---|
| BC9101A-L25-15 | 90–264 VAC | 25 | 15 | 1800 | 120 |
| BC9101A-L40-15 | 90–264 VAC | 40 | 15 | 1800 | 120 |
| BC9101A-L60-15 | 90–264 VAC | 60 | 15 | 1800 | 120 |
| BC9101A-L25-25 | 90–264 VAC | 25 | 25 | 3000 | 70 |
| BC9101A-L40-25 | 90–264 VAC | 40 | 25 | 3000 | 70 |
| BC9101A-L60-25 | 90–264 VAC | 60 | 25 | 3000 | 70 |
| BC9101B-L15 | 90–264 VAC | — | 15 | 1800 | 120 |
| BC9101B-L25 | 90–264 VAC | — | 25 | 3000 | 70 |
| Reference | Space-height ratio | Mounting height | Equivalent metal-halide wattage (catalogue) | PDF page |
|---|---|---|---|---|
| BC9101A-L25-15 | — | 2–5 m | 70 W / 35 W | 88 |
| BC9101A-L40-15 | — | 2–5 m | 100 W / 35 W | 88 |
| BC9101A-L60-15 | — | 3–8 m | 150 W / 35 W | 88 |
| BC9101A-L25-25 | — | 2–5 m | 70 W / 70 W | 88 |
| BC9101A-L40-25 | — | 2–5 m | 100 W / 70 W | 88 |
| BC9101A-L60-25 | — | 3–8 m | 150 W / 70 W | 88 |
| BC9101B-L15 | — | 2–5 m | 35 W | 88 |
| BC9101B-L25 | — | 2–5 m | 70 W | 88 |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

Original catalogue extract · 2 pages · PDF · 441 KB
View documentOriginal catalogue pages 87, 88