Rectangular beam choices
The listed 60° × 80° and 90° × 110° distributions have separate power and light-output rows.
HAZARDOUS AREA LIGHTING
BC9307S combines a bracket-mounted housing with 100–240 W catalogue configurations for industrial work areas and equipment platforms. Two rectangular distributions allow the light pattern to be selected alongside the mounting layout.
The listed 60° × 80° and 90° × 110° distributions have separate power and light-output rows.
The catalogue provides seat, side-wall and pole mounting drawings for the bracket light.
The bracket and exposed fasteners use 304 stainless steel around the treated aluminium housing.
The design includes an independent wiring chamber and a replaceable light source that does not require on-site welding.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Beam distribution | Catalogue mounting height (m) | Space-height ratio | Catalogue luminous flux | Select |
|---|---|---|---|---|---|---|---|
| BC9307S-L100-60°×80° | 90–264 VAC | 100 W | 60°×80° | 8–12 m | 1.25 | 11,800 lm | |
| BC9307S-L120-60°×80° | 90–264 VAC | 120 W | 60°×80° | 8–12 m | 1.25 | 13,600 lm | |
| BC9307S-L150-60°×80° | 90–264 VAC | 150 W | 60°×80° | 10–15 m | 1.25 | 17,300 lm | |
| BC9307S-L200-60°×80° | 90–264 VAC | 200 W | 60°×80° | 10–15 m | 1.25 | 23,300 lm | |
| BC9307S-L240-60°×80° | 90–264 VAC | 240 W | 60°×80° | 15–20 m | 1.25 | 26,700 lm | |
| BC9307S-L100-90°×110° | 90–264 VAC | 100 W | 90°×110° | 8–12 m | 1.75 | 11,000 lm | |
| BC9307S-L120-90°×110° | 90–264 VAC | 120 W | 90°×110° | 8–12 m | 1.75 | 12,600 lm | |
| BC9307S-L150-90°×110° | 90–264 VAC | 150 W | 90°×110° | 10–15 m | 1.75 | 16,000 lm | |
| BC9307S-L200-90°×110° | 90–264 VAC | 200 W | 90°×110° | 10–15 m | 1.75 | 22,000 lm | |
| BC9307S-L240-90°×110° | 90–264 VAC | 240 W | 90°×110° | 15–20 m | 1.75 | 25,300 lm |
| Input voltage (V) | 90~264VAC |
|---|---|
| Rated frequency | 50Hz / 60Hz |
| CRI (Ra) | 70 (80 optional) |
| Life time (h) | 50,000 |
| CCT | 5000K(3000K/4000K optional) |
| Printed Ex marking | Ex db eb IIC T4/T3 Gb; Ex tb IIIC T130°C/T195°C Db |
| Ambient options printed in catalogue | −50 to +40 / +55 °C; exact variant and temperature class to be confirmed |
| Catalogue application areas | Gas Zones 1 and 2; dust Zones 21 and 22. Confirm the applicable model marking and installation conditions. |
| Cable entry | M20×1.5, G3/4", NPT1/2" |
|---|---|
| Terminals | Multi core: ≤4mm²; Single core: ≤6mm² |
| Dimension (mm) | 295×330×350 |
| Net weight (kg) | 7.5 |
| Ingress protection | IP66 |
| ATEX certificate: | EPT 16 ATEX 2484 X Archived copy on this site; confirm current status before specification. |
|---|---|
| IECEx certificate: | IECEx CML 24.0116X Archived copy on this site; confirm current status before specification. |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P07 | 1 | M20 waterproof plug | 1 | For Ø8–12 mm cable |
| P07 | 2 | Vertical mounting pole | 1 | For Ø40–50 mm pole |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P23 | 3 | Inclined bracket | 1 |
| Reference | Space-height ratio | Mounting height | Equivalent metal-halide wattage (catalogue) | PDF page |
|---|---|---|---|---|
| BC9307S-L100-60°×80° | 1.25 | 8–12 m | 250 W | 51 |
| BC9307S-L120-60°×80° | 1.25 | 8–12 m | >250 W | 51 |
| BC9307S-L150-60°×80° | 1.25 | 10–15 m | 400 W | 51 |
| BC9307S-L200-60°×80° | 1.25 | 10–15 m | >400 W | 51 |
| BC9307S-L240-60°×80° | 1.25 | 15–20 m | 600–800 W | 51 |
| BC9307S-L100-90°×110° | 1.75 | 8–12 m | 250 W | 52 |
| BC9307S-L120-90°×110° | 1.75 | 8–12 m | >250 W | 52 |
| BC9307S-L150-90°×110° | 1.75 | 10–15 m | 400 W | 52 |
| BC9307S-L200-90°×110° | 1.75 | 10–15 m | >400 W | 52 |
| BC9307S-L240-90°×110° | 1.75 | 15–20 m | 600–800 W | 52 |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.


Original catalogue extract · 2 pages · PDF · 380 KB
View documentOriginal catalogue pages 51, 52