Locking mounting bracket
The bracket can be aimed and locked to the required direction.
HAZARDOUS AREA LIGHTING
BC9101 is an explosion proof LED floodlight with an adjustable, locking bracket. Select the ordering code against the available supply: standard AC and selected low-voltage configurations are listed separately below. Compare other series in the floodlight range.
The bracket can be aimed and locked to the required direction.
The reflector layout is designed to distribute illumination across the work area.
An aluminium housing, treated surface and 304 stainless steel exposed fasteners form the external assembly.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Catalogue luminous flux | Select |
|---|---|---|---|---|
| BC9101-L25 | 90–305 VAC | 25 W | 2,800 lm | |
| BC9101-L40 | 90–305 VAC | 40 W | 4,200 lm | |
| BC9101-L60 | 90–305 VAC | 60 W | 5,900 lm | |
| BC9101-L80 | 90–305 VAC | 80 W | 7,200 lm | |
| BC9101-L25L | 18–43 VAC / 18–55 VDC | 25 W | 2,800 lm | |
| BC9101-L40L | 18–43 VAC / 18–55 VDC | 40 W | 4,200 lm |
| Input voltage (V) | 90~305VAC; 18~43VAC/ 18~55VDC (low) (optional) |
|---|---|
| Rated frequency | 50Hz / 60Hz |
| Light source | LED |
| Life time (h) | 100,000 |
| CRI (Ra) | 75 |
| CCT | 5000K ±250K |
| Printed Ex marking | Ex db IIB T6 Gb; Ex tb IIIC T80°C Db |
| Ambient options printed in catalogue | −40 to +45 °C; exact variant and temperature class to be confirmed |
| Catalogue application areas | Gas Zones 1 and 2; dust Zones 21 and 22. Confirm the applicable model marking and installation conditions. |
| Cable entry | G3/4" |
|---|---|
| Dimension (mm) | 326×370×88 |
| Net weight (kg) | 9 |
| Ingress protection | IP66 |
| ATEX certificate: | CNEX 23 ATEX 0009 X Archived copy on this site; confirm current status before specification. |
|---|---|
| IECEx certificate: | IECEx CNEX 23.0006X Archived copy on this site; confirm current status before specification. |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

Original catalogue extract · 2 pages · PDF · 506 KB
View documentOriginal catalogue pages 20, 21
View document