Two rectangular distributions
The catalogue lists separate light-output rows for the 60° × 80° and 90° × 110° optics.
HAZARDOUS AREA LIGHTING
BC9309S provides higher-output fixed floodlighting for oilfield, chemical, offshore and other industrial facilities. Standard floodlight references use 60° × 80° or 90° × 110° distributions.
The catalogue lists separate light-output rows for the 60° × 80° and 90° × 110° optics.
Seat-mounting layouts S1 and S2 and a side-wall arrangement are shown for installation planning.
The housing combines a finned thermal structure with stainless steel external hardware and brackets.
The wiring chamber is independent, and the light source can be replaced without welding.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Beam distribution | Catalogue mounting height (m) | Space-height ratio | Catalogue luminous flux | Select |
|---|---|---|---|---|---|---|---|
| BC9309S-L240-60°×80° | 200–277 VAC | 240 W | 60°×80° | 15–25 m | 1.35 | 27,200 lm | |
| BC9309S-L300-60°×80° | 200–277 VAC | 300 W | 60°×80° | 15–25 m | 1.35 | 34,600 lm | |
| BC9309S-L400-60°×80° | 200–277 VAC | 400 W | 60°×80° | 15–25 m | 1.35 | 46,600 lm | |
| BC9309S-L480-60°×80° | 200–277 VAC | 480 W | 60°×80° | 15–25 m | 1.35 | 53,400 lm | |
| BC9309S-L240-90°×110° | 200–277 VAC | 240 W | 90°×110° | 15–20 m | 1.4 | 25,200 lm | |
| BC9309S-L300-90°×110° | 200–277 VAC | 300 W | 90°×110° | 15–20 m | 1.4 | 32,000 lm | |
| BC9309S-L400-90°×110° | 200–277 VAC | 400 W | 90°×110° | 15–20 m | 1.4 | 44,000 lm | |
| BC9309S-L480-90°×110° | 200–277 VAC | 480 W | 90°×110° | 15–20 m | 1.4 | 50,600 lm |
| Rated voltage (V) | 200~277VAC |
|---|---|
| Rated frequency | 50Hz / 60Hz |
| Light source | LED |
| Life time (h) | 50,000 |
| CRI | Ra 70 (80 optional) |
| CCT | 5000K(3000K/4000K optional) |
| Printed Ex marking | Ex nR IIC T3/T4 Gc; Ex tD A21 IP66 T195°C/T130°C |
| Ambient options printed in catalogue | −50 to +40 / +55 °C; exact variant and temperature class to be confirmed |
| Leading-in cable diameter | φ8mm~φ12mm |
|---|---|
| Dimension (mm) | 602×250×340 |
| Net Weight (kg) | 13 |
| Ingress protection | IP66 |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Reference | Space-height ratio | Mounting height | Equivalent metal-halide wattage (catalogue) | PDF page |
|---|---|---|---|---|
| BC9309S-L240-60°×80° | 1.35 | 15–25 m | 600 W | 63 |
| BC9309S-L300-60°×80° | 1.35 | 15–25 m | 1000 W | 63 |
| BC9309S-L400-60°×80° | 1.35 | 15–25 m | >1000 W | 63 |
| BC9309S-L480-60°×80° | 1.35 | 15–25 m | / | 63 |
| BC9309S-L240-90°×110° | 1.4 | 15–20 m | 600 W | 64 |
| BC9309S-L300-90°×110° | 1.4 | 15–20 m | 1000 W | 64 |
| BC9309S-L400-90°×110° | 1.4 | 15–20 m | >1000 W | 64 |
| BC9309S-L480-90°×110° | 1.4 | 15–20 m | / | 64 |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.


Original catalogue extract · 2 pages · PDF · 364 KB
View documentOriginal catalogue pages 63, 64