BZA5200 Explosion Proof Control Station — product image

EXPLOSION PROOF ELECTRICAL EQUIPMENT

BZA5200 Explosion Proof Control Station

BZA5200 provides compact push-button, meter and indicator units. The catalogue separates emergency-stop, ordinary-button and indicator choices, with voltage, colour or contact details specified for the selected component.

Rated current
10 A
Utilization category
AC-15 / DC-13
Ingress protection
IP66
Control options
Push buttons / meters / indicators

Individual control units with defined component codes

Push-button choices

Emergency-stop and ordinary-button units can be specified with the listed contact arrangements.

Indicator voltage and colour

D1–D4 indicator codes each have a defined supply range, with red, green, yellow, white and blue colour codes.

Meter selection

Ammeter and voltmeter requirements are defined by measurement range and, where needed, transformer ratio.

Hanging installation

The source specifies hanging installation with a threaded cable entry for the control unit.

Choose your configuration

Select a listed catalogue reference and add your installation requirements.

Additional installation and specification requirements are confirmed with your quotation.

Catalogue configurations

ModelComponentIndicator voltageIndicator colourSelect
BZA5200-A1Emergency stop button——
BZA5200-A2Ordinary button——
BZA5200-BVoltmeter / ammeter——
BZA5200-D1RIndicator light24–36 V AC/DCRed
BZA5200-D1GIndicator light24–36 V AC/DCGreen
BZA5200-D1YIndicator light24–36 V AC/DCYellow
BZA5200-D1WIndicator light24–36 V AC/DCWhite
BZA5200-D1BIndicator light24–36 V AC/DCBlue
BZA5200-D2RIndicator light220–380 V ACRed
BZA5200-D2GIndicator light220–380 V ACGreen
BZA5200-D2YIndicator light220–380 V ACYellow
BZA5200-D2WIndicator light220–380 V ACWhite
BZA5200-D2BIndicator light220–380 V ACBlue
BZA5200-D3RIndicator light12–60 V DCRed
BZA5200-D3GIndicator light12–60 V DCGreen
BZA5200-D3YIndicator light12–60 V DCYellow
BZA5200-D3WIndicator light12–60 V DCWhite
BZA5200-D3BIndicator light12–60 V DCBlue
BZA5200-D4RIndicator light110–240 V AC/DCRed
BZA5200-D4GIndicator light110–240 V AC/DCGreen
BZA5200-D4YIndicator light110–240 V AC/DCYellow
BZA5200-D4WIndicator light110–240 V AC/DCWhite
BZA5200-D4BIndicator light110–240 V AC/DCBlue

Technical specifications

Electrical and performance data

Rated voltage220 / 380 V AC; 230 / 400 V AC; 220 V DC
Rated current (A)10
Utilization categoryAC-15 / DC-13
Wiring methodCable wiring; steel pipe wiring to be specified
Internal componentsPush buttons, meters and indicator lights
Printed gas / dust markingEx db IIC T6 Gb / Ex tb IIIC T80 °C Db
Reference standardsGB/T 3836.1, .2, .31; IEC 60079-0, -1, -31; EN 60079-0, -1, -31
Catalogue application areasGas Zones 1 and 2; dust Zones 21 and 22. Select the applicable protection version.

Housing and installation data

Ingress protectionIP66
Corrosion gradeWF1 / WF2
Catalogue ambient-temperature options−40 to +55 °C
Cable-entry threadG¾″; specify other requirements
Applicable cable outer diameterØ10–14 mm
Installation methodHanging

Current-transformer ammeter input

Secondary current1 A or 5 A
SelectionSpecify the transformer ratio and required scale; this is separate from a direct-connected 0–1 A ammeter.

Dimensions and mounting

Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.

BZA5200 original dimension and mounting drawing
A1 emergency stop, A2 pushbutton, B meter and D indicator · dimensions and installation

Button and indicator code logic

Button and indicator code logic
Component codeDescriptionSupply / contact requirement
A1Emergency-stop buttonContact code 11 /20 /02
A2Ordinary buttonContact code 11 /20 /02
D1Indicator light24–36 V AC/DC
D2Indicator light220–380 V AC
D3Indicator light12–60 V DC
D4Indicator light110–240 V AC/DC

Button contacts and indicator colours

Button contacts and indicator colours
CodeMeaning
111 NO +1 NC
202 NO
022 NC
RRed
GGreen
YYellow
WWhite
BBlue

Ammeter selection

Ammeter selection
Measurement methodRange / inputOverload multipleNet weight (kg)
Direct0–20/40 mA; 4–20/40 mA2×0.71
Direct0–1 A;0–5 A2×0.71
Current transformerSecondary 1 A or 5 A2× or6×0.71

Voltmeter selection

Voltmeter selection
Measurement methodRange / secondaryNet weight (kg)
Direct0–10 /25 /40 /60 /100 /150 /250 /300 /450 /500 V0.8
Voltage transformerSecondary100 /110 /120 V0.8

Printed ordering examples

Printed ordering examples
ReferenceMeaning
BZA5200-A1Mushroom-head emergency stop button, 1 NO + 1 NC
BZA5200-D2RAC 220–380 V red indicator light

Button and indicator bodies

Button and indicator bodies
ComponentAvailable coloursNet weight (kg)
Emergency-stop buttonRed0.77
Ordinary buttonRed / green0.71
Indicator lightRed / green / yellow / white / blue0.71

Installation notes

  • Original dimension drawings are provided for emergency-stop, ordinary-button, meter and indicator units.

Ordering notes

  • Select the component, contact arrangement or measurement range, and indicator supply/colour together.
  • State special requirements and steel-pipe wiring where needed.
  • Confirm the exact protection version, temperature class and ambient conditions against the applicable model documents.

Product documents

BZA5200 · product datasheet

Original catalogue extract · 4 pages · PDF · 1390 KB

View document

BZA5200 · 2024 TORMIN Explosion Proof Electrical Equipment Catalogue

Original catalogue pages 27, 28, 29, 30

View document

Tell us what you need.

Fields marked * are required.

Your details will be used to respond to this enquiry.