External module replacement
The modular assembly permits module replacement without opening the complete fixture.
INDUSTRIAL LIGHTING
ZY8102 provides fixed floodlighting for facilities such as power plants, substations, factories and docks.
The modular assembly permits module replacement without opening the complete fixture.
The rear module heat-sink arrangement provides an open thermal path around the LED modules.
The aluminium-alloy body uses 304 stainless steel exposed fasteners and an angle-locking bracket.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Beam distribution | Catalogue luminous flux | Select |
|---|---|---|---|---|---|
| ZY8102-L80-80°×100° | Technical Parameters 90~305VAC | 80 W | 80°×100° | 8,800 lm | |
| ZY8102-L100-80°×100° | Technical Parameters 90~305VAC | 100 W | 80°×100° | 11,000 lm | |
| ZY8102-L180-80°×100° | Technical Parameters 90~305VAC | 180 W | 80°×100° | 18,900 lm | |
| ZY8102-L240-80°×100° | Technical Parameters 90~305VAC | 240 W | 80°×100° | 25,200 lm | |
| ZY8102-L300-80°×100° | Technical Parameters 90~305VAC | 300 W | 80°×100° | 31,500 lm | |
| ZY8102-L120-80°×100° | Technical Parameters 90~305VAC | 120 W | 80°×100° | 12,200 lm | |
| ZY8102-L150-80°×100° | Technical Parameters 90~305VAC | 150 W | 80°×100° | 16,500 lm |
| Input voltage | 90–305 VAC |
|---|---|
| Frequency | 50/60 Hz |
| Light source lifetime | 100,000 h |
| CRI | Ra75 |
| CCT | 5000 K ±250 K |
| Cable diameter | Ø6–Ø8 mm |
|---|
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Power group | Dimensions (mm) | Net weight (kg) |
|---|---|---|
| 80 / 100 / 120 W | 322 × 363 × 150 | 5.2 |
| 150 / 180 W | 417 × 363 × 150 | 6.2 |
| 240 W | 512 × 363 × 150 | 7.2 |
| 300 W | 607 × 363 × 150 | 8.2 |
| Order number | Item | Specification | Quantity | Application / note |
|---|---|---|---|---|
| P13 | 1 | Ceiling mounting bracket | 2 |
| Catalogue reference | Power (W) | Beam | Input voltage | Catalogue output (lm) | Equivalent to |
|---|---|---|---|---|---|
| ZY8102-L80-80°×100° | 80 | 80°×100° | Technical Parameters 90~305VAC | 8800 | 175W~250W 250W 250W~400W 50 40 400W 400W~600W 0lm .0 600W 0.0 600W~1000W |
| ZY8102-L100-80°×100° | 100 | 80°×100° | Technical Parameters 90~305VAC | 11000 | 175W~250W 250W 250W~400W 50 40 400W 400W~600W 0lm .0 600W 0.0 600W~1000W |
| ZY8102-L180-80°×100° | 180 | 80°×100° | Technical Parameters 90~305VAC | 18900 | 175W~250W 250W 250W~400W 50 40 400W 400W~600W 0lm .0 600W 0.0 600W~1000W |
| ZY8102-L240-80°×100° | 240 | 80°×100° | Technical Parameters 90~305VAC | 25200 | 175W~250W 250W 250W~400W 50 40 400W 400W~600W 0lm .0 600W 0.0 600W~1000W |
| ZY8102-L300-80°×100° | 300 | 80°×100° | Technical Parameters 90~305VAC | 31500 | 175W~250W 250W 250W~400W 50 40 400W 400W~600W 0lm .0 600W 0.0 600W~1000W |
| ZY8102-L120-80°×100° | 120 | 80°×100° | Technical Parameters 90~305VAC | 12200 | |
| ZY8102-L150-80°×100° | 150 | 80°×100° | Technical Parameters 90~305VAC | 16500 |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

Original catalogue extract · 1 pages · PDF · 462 KB
View documentOriginal catalogue pages 18
View document