Normal plus emergency or emergency-only
The AP/BP model choice determines the fixture’s normal-supply operating arrangement.
HAZARDOUS AREA LIGHTING
BC9306AP and BC9306BP provide emergency lighting for industrial areas such as oilfields, chemical facilities and platforms. AP references include normal lighting; BP references provide emergency operation.
The AP/BP model choice determines the fixture’s normal-supply operating arrangement.
The emergency ordering table lists 60°, 80°, 100° and 200° references, with output tied to emergency wattage.
Cable termination is accommodated in a separate wiring chamber.
The installation pages cover pole, wall, ceiling, flange and guardrail arrangements for the P-family body.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Beam distribution | Emergency power | Emergency duration | Operation | Space-height ratio | Emergency luminous flux | Select |
|---|---|---|---|---|---|---|---|---|---|
| BC9306AP-L40-15-60° | 90–264 VAC | 40 W | 60° | 15 W | 120 min | Maintained emergency | 0.9 | 1,800 lm | |
| BC9306AP-L40-25-60° | 90–264 VAC | 40 W | 60° | 25 W | 70 min | Maintained emergency | 0.9 | 3,300 lm | |
| BC9306AP-L40-15-80° | 90–264 VAC | 40 W | 80° | 15 W | 120 min | Maintained emergency | 1.35 | 1,800 lm | |
| BC9306AP-L40-25-80° | 90–264 VAC | 40 W | 80° | 25 W | 70 min | Maintained emergency | 1.35 | 3,300 lm | |
| BC9306AP-L40-15-100° | 90–264 VAC | 40 W | 100° | 15 W | 120 min | Maintained emergency | 1.4 | 1,800 lm | |
| BC9306AP-L40-25-100° | 90–264 VAC | 40 W | 100° | 25 W | 70 min | Maintained emergency | 1.4 | 3,300 lm | |
| BC9306AP-L40-15-200° | 90–264 VAC | 40 W | 200° | 15 W | 120 min | Maintained emergency | 1.75 | 1,400 lm | |
| BC9306AP-L40-25-200° | 90–264 VAC | 40 W | 200° | 25 W | 70 min | Maintained emergency | 1.75 | 2,600 lm | |
| BC9306BP-15-60° | 90–264 VAC | — | 60° | 15 W | 120 min | Auto emergency | 0.9 | 1,800 lm | |
| BC9306BP-25-60° | 90–264 VAC | — | 60° | 25 W | 70 min | Auto emergency | 0.9 | 3,300 lm | |
| BC9306BP-15-80° | 90–264 VAC | — | 80° | 15 W | 120 min | Auto emergency | 1.35 | 1,800 lm | |
| BC9306BP-25-80° | 90–264 VAC | — | 80° | 25 W | 70 min | Auto emergency | 1.35 | 3,300 lm | |
| BC9306BP-15-100° | 90–264 VAC | — | 100° | 15 W | 120 min | Auto emergency | 1.4 | 1,800 lm | |
| BC9306BP-25-100° | 90–264 VAC | — | 100° | 25 W | 70 min | Auto emergency | 1.4 | 3,300 lm | |
| BC9306BP-15-200° | 90–264 VAC | — | 200° | 15 W | 120 min | Auto emergency | 1.75 | 1,400 lm | |
| BC9306BP-25-200° | 90–264 VAC | — | 200° | 25 W | 70 min | Auto emergency | 1.75 | 2,600 lm |
| Input voltage (V) | 90~264VAC |
|---|---|
| Rated frequency | 50Hz / 60Hz |
| Light source | LED |
| CRI (Ra) | 70 (80 optional) |
| Life time (h) | 50,000 |
| CCT | 4000K(3000K/5000K optional) |
| Time of charging (h) | >6 |
| Rated capacity | 2.6Ah / 14.8V |
| Printed Ex marking | Ex db eb IIC T6/T5 Gb; Ex tb IIIC T80°C/T95°C Db |
| Catalogue application areas | Gas Zones 1 and 2; dust Zones 21 and 22. Confirm the applicable model marking and installation conditions. |
| Cable entry | M20×1.5, M25×1.5, NPT3/4", NPT1/2", G3/4" |
|---|---|
| Leading-in cable diameter | φ10mm~φ14mm |
| Terminals | Multi core: ≤2.5mm2; Single core: ≤4mm² |
| Dimension (mm) | φ230×270 |
| Net weight (kg) | 4.2 |
| Ingress protection | IP66 |
| ATEX certificate: | EPT 16 ATEX 2484 X Archived copy on this site; confirm current status before specification. |
|---|---|
| IECEx certificate: | IECEx CML 24.0116X Archived copy on this site; confirm current status before specification. |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Catalogue reference | Input voltage | Normal / rated power (W) | Beam | Emergency power (W) | Emergency output (lm) | Emergency duration (min) |
|---|---|---|---|---|---|---|
| BC9306AP-L40-15-60° | 90–264 VAC | 40 | 60° | 15 | 1800 | 120 |
| BC9306AP-L40-25-60° | 90–264 VAC | 40 | 60° | 25 | 3300 | 70 |
| BC9306AP-L40-15-80° | 90–264 VAC | 40 | 80° | 15 | 1800 | 120 |
| BC9306AP-L40-25-80° | 90–264 VAC | 40 | 80° | 25 | 3300 | 70 |
| BC9306AP-L40-15-100° | 90–264 VAC | 40 | 100° | 15 | 1800 | 120 |
| BC9306AP-L40-25-100° | 90–264 VAC | 40 | 100° | 25 | 3300 | 70 |
| BC9306AP-L40-15-200° | 90–264 VAC | 40 | 200° | 15 | 1400 | 120 |
| BC9306AP-L40-25-200° | 90–264 VAC | 40 | 200° | 25 | 2600 | 70 |
| BC9306BP-15-60° | 90–264 VAC | — | 60° | 15 | 1800 | 120 |
| BC9306BP-25-60° | 90–264 VAC | — | 60° | 25 | 3300 | 70 |
| BC9306BP-15-80° | 90–264 VAC | — | 80° | 15 | 1800 | 120 |
| BC9306BP-25-80° | 90–264 VAC | — | 80° | 25 | 3300 | 70 |
| BC9306BP-15-100° | 90–264 VAC | — | 100° | 15 | 1800 | 120 |
| BC9306BP-25-100° | 90–264 VAC | — | 100° | 25 | 3300 | 70 |
| BC9306BP-15-200° | 90–264 VAC | — | 200° | 15 | 1400 | 120 |
| BC9306BP-25-200° | 90–264 VAC | — | 200° | 25 | 2600 | 70 |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P01 | 1 | G¾″ pole, 30 cm | 1 | |
| BHD01 | 2 | Explosion proof junction box | 1 |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P03 | 1 | Expansion screw hook | 1 | |
| P03 | 2 | Chain | 1 | |
| P03 | 3 | C–C turnbuckle | 1 | |
| P03 | 4 | G¾″ bend pipe, 150° | 1 | |
| BHD01 | 5 | Explosion proof junction box | 1 |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P04 | 1 | Expansion screw hook | 1 | |
| P04 | 2 | Chain | 1 | |
| P04 | 3 | C–C turnbuckle | 1 | |
| P04 | 4 | G¾″ bend pipe, 90° | 1 | |
| BHD01 | 5 | Explosion proof junction box | 1 |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| BHD01 | 1 | Explosion proof junction box | 1 | |
| P02 | 2 | G¾″ adapter, male–male | 1 |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P06 | 1 | Flange pole | 1 |
| Kit / reference | Item | Description | Quantity | Notes |
|---|---|---|---|---|
| P05 | 1 | Fence pole | 1 | |
| P05 | 2 | U-type bolts | 2 |
| Reference | Space-height ratio | Mounting height | Equivalent metal-halide wattage (catalogue) | PDF page |
|---|---|---|---|---|
| BC9306AP-L40-15-60° | 0.9 | — | 100 W / 35 W | 90 |
| BC9306AP-L40-25-60° | 0.9 | — | 100 W / 70 W | 90 |
| BC9306AP-L40-15-80° | 1.35 | — | 100 W / 35 W | 90 |
| BC9306AP-L40-25-80° | 1.35 | — | 100 W / 70 W | 90 |
| BC9306AP-L40-15-100° | 1.4 | — | 100 W / 35 W | 90 |
| BC9306AP-L40-25-100° | 1.4 | — | 100 W / 70 W | 90 |
| BC9306AP-L40-15-200° | 1.75 | — | 100 W / 35 W | 90 |
| BC9306AP-L40-25-200° | 1.75 | — | 100 W / 70 W | 90 |
| BC9306BP-15-60° | 0.9 | — | 35 W | 90 |
| BC9306BP-25-60° | 0.9 | — | 70 W | 90 |
| BC9306BP-15-80° | 1.35 | — | 35 W | 90 |
| BC9306BP-25-80° | 1.35 | — | 70 W | 90 |
| BC9306BP-15-100° | 1.4 | — | 35 W | 90 |
| BC9306BP-25-100° | 1.4 | — | 70 W | 90 |
| BC9306BP-15-200° | 1.75 | — | 35 W | 90 |
| BC9306BP-25-200° | 1.75 | — | 70 W | 90 |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

Original catalogue extract · 4 pages · PDF · 462 KB
View documentOriginal catalogue pages 89, 90, 91, 92
View document