Beam-specific performance
Compare 60° × 80°, 90° × 110° and 200° distributions. Luminous output is listed for each power and beam combination, so you can select against the actual configuration.
HAZARDOUS AREA LIGHTING
Bracket-mounted LED lighting with three standard beam distributions, 30–80 W AC models and dedicated 25 / 40 / 60 W low-voltage versions.
BUILT AROUND YOUR INSTALLATION
The BC9306S combines an aluminum housing, 304 stainless steel bracket and exposed fasteners, and an independent wiring chamber. Three standard distributions cover different lighting layouts. Start with your electrical supply, then compare power and beam options against the required coverage and illuminance.
Compare 60° × 80°, 90° × 110° and 200° distributions. Luminous output is listed for each power and beam combination, so you can select against the actual configuration.
Standard versions use 90–264 VAC. Dedicated low voltage models use 18–43 VAC or 18–55 VDC and are listed at 25, 40 and 60 W.
An aluminum housing with an anti-corrosion surface coating, 304 stainless steel bracket and exposed fasteners, and IP66 protection supports demanding industrial installations.
Choose seat, ceiling, side wall or pole mounting. The separate wiring chamber provides access for installation, and optional pole mounting accessories are listed under P07.
POWER · OPTICS · INSTALLATION
Select a listed supply, power and beam combination. Add the installation details to your enquiry.
Ra70 is standard; Ra80 can be requested. CCT, CRI and installation choices accompany the catalogue reference and are confirmed with your quotation.
Confirm output for optional CCT / CRI. The 18° spotlight is a separate version.
Enquire about this configurationChoose standard AC for 90–264 VAC, or a dedicated low voltage model for 18–43 VAC / 18–55 VDC.
Use 60° × 80° or 90° × 110° for directional coverage, or 200° for a broad distribution. Confirm the final layout against mounting height, target illuminance and photometric data.
Read the luminous flux for the selected beam and power together. At 80 W, the standard versions provide 8,800 lm at 60° × 80°, 8,400 lm at 90° × 110°, or 6,800 lm at 200°.
Specify mounting, cable entry, CCT, CRI, site classification and ambient temperature. Standard CCT is 5000 K, with 3000 K and 4000 K options; standard CRI is Ra70, with Ra80 available as an option.
CATALOGUE CONFIGURATIONS
Read the output for each beam and power together. The low-voltage models have their own references with an additional L suffix.
| Catalogue reference | Power | Distribution | Luminous flux | Select |
|---|---|---|---|---|
| BC9306S-L30-60°×80° | 30 W | 60° × 80° | 3,500 lm | |
| BC9306S-L40-60°×80° | 40 W | 60° × 80° | 4,600 lm | |
| BC9306S-L50-60°×80° | 50 W | 60° × 80° | 5,600 lm | |
| BC9306S-L60-60°×80° | 60 W | 60° × 80° | 6,900 lm | |
| BC9306S-L80-60°×80° | 80 W | 60° × 80° | 8,800 lm | |
| BC9306S-L30-90°×110° | 30 W | 90° × 110° | 3,400 lm | |
| BC9306S-L40-90°×110° | 40 W | 90° × 110° | 4,400 lm | |
| BC9306S-L50-90°×110° | 50 W | 90° × 110° | 5,600 lm | |
| BC9306S-L60-90°×110° | 60 W | 90° × 110° | 6,700 lm | |
| BC9306S-L80-90°×110° | 80 W | 90° × 110° | 8,400 lm | |
| BC9306S-L30-200° | 30 W | 200° | 2,800 lm | |
| BC9306S-L40-200° | 40 W | 200° | 3,700 lm | |
| BC9306S-L50-200° | 50 W | 200° | 4,500 lm | |
| BC9306S-L60-200° | 60 W | 200° | 5,400 lm | |
| BC9306S-L80-200° | 80 W | 200° | 6,800 lm |
| Catalogue reference | Power | Distribution | Luminous flux | Select |
|---|---|---|---|---|
| BC9306S-L25L-60°×80° | 25 W | 60° × 80° | 2,900 lm | |
| BC9306S-L40L-60°×80° | 40 W | 60° × 80° | 4,600 lm | |
| BC9306S-L60L-60°×80° | 60 W | 60° × 80° | 6,900 lm | |
| BC9306S-L25L-90°×110° | 25 W | 90° × 110° | 2,700 lm | |
| BC9306S-L40L-90°×110° | 40 W | 90° × 110° | 4,400 lm | |
| BC9306S-L60L-90°×110° | 60 W | 90° × 110° | 6,700 lm | |
| BC9306S-L25L-200° | 25 W | 200° | 2,400 lm | |
| BC9306S-L40L-200° | 40 W | 200° | 3,700 lm | |
| BC9306S-L60L-200° | 60 W | 200° | 5,400 lm |
All values above are catalogue figures for the listed references. Confirm photometric performance for optional CCT / CRI and the final installation layout. For the separate 18° version, see BC9306S Spotlight.
TECHNICAL DETAILS
| Light source | LED |
|---|---|
| Standard AC supply | 90–264 VAC · 50 / 60 Hz |
| Low-voltage supply | 18–43 VAC / 18–55 VDC |
| AC power options | 30 / 40 / 50 / 60 / 80 W |
| Low-voltage power | 25 / 40 / 60 W |
| Beam distributions | 60° × 80° / 90° × 110° / 200° |
| Optional control / lenses | The catalogue lists 1–10 VDC, PWM, carrier and DALI dimming, and custom 40°, 60°, 80° and 100° lenses. Request these options with the enquiry; availability, output and applicable certification must be confirmed for the exact configuration. |
| Colour temperature | 5000 K standard; 3000 / 4000 K optional |
| Colour rendering | Ra70 standard; Ra80 optional |
| Catalogue life figure | 50,000 hours |
| Housing | Aluminium, anti-corrosion surface coating |
|---|---|
| Bracket / fasteners | 304 stainless steel |
| Ingress protection | IP66 |
| Catalogue ambient options | Minimum −50 °C; upper limits +40 °C or +55 °C, depending on the configuration. Confirm the exact reference, temperature class and permitted ambient range in its applicable model documents. |
| Dimensions | 245 × 260 × 270 mm |
| Net weight | 4.9 kg |
| Cable entry options | M20 × 1.5 / NPT ½″ |
| Terminal cross-section | Multi-core ≤2.5 mm²; single-core ≤4 mm² |
| Mounting | Seat / ceiling / side wall / pole |
| Wiring access | Independent wiring chamber |
| ATEX certificate: | EPT 16 ATEX 2484 X Archived copy on this site; confirm current status before specification. |
|---|---|
| IECEx certificate: | IECEx CML 24.0116X Archived copy on this site; confirm current status before specification. |
DIMENSIONS & ACCESSORIES
Standard and low-voltage versions use the dimensions shown here. Review the drawing and specify the mounting arrangement with your enquiry.

OPTIONAL ACCESSORY KIT
Request P07 when specifying a pole installation. The catalogue lists the following items separately from the luminaire.
| M20 waterproof plug | 1 pc · Ø8–12 mm cable |
|---|---|
| Vertical mounting pole | 1 pc · Ø40–50 mm pole |
Confirm accessory inclusion in the final quotation.
For the 18° spotlight, use its separate 291 × 260 × 270 mm drawing.
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

MODEL DOCUMENTS
Use the current applicable certificate and its conditions to confirm the exact model, temperature class and permitted ambient range.
| Gas areas · catalogue | Zone 1 / 2 · IIA, IIB, IIC |
|---|---|
| Gas Ex marking | Ex db eb IIC T6/T5/T4 Gb |
| Dust areas · catalogue | Zone 21 / 22 |
| Dust Ex marking | Ex tb IIIC T80°C/T95°C/T130°C Db |
Temperature classes and ambient limits vary by configuration. The website's family certificate copies are identified as archived, with current status unverified. Ask TORMIN for the applicable documentation for the selected reference.
Visit the certification library ↗Standard AC and low-voltage configurations, technical data and mounting drawing. Original catalogue pages 040–042.
Download PDF · 3 pages ↗Seat, ceiling, side wall and pole arrangements, plus the P07 accessory listing.
Open full-size drawing ↗BC9306 / BC9307 family document. Check the original schedule for exact variant coverage and special conditions.
Review original ATEX PDF ↗BC9306 / BC9307 family document. Check the original schedule for exact variant coverage and special conditions.
Review original IECEx PDF ↗Need IES / LDT files or installation instructions? Include the selected reference with your request.
Original catalogue page 041 lists the following spacing and mounting-height guidance, together with indicative metal-halide (MH) replacement wattages. Use these values for initial selection; confirm illuminance, coverage and replacement suitability using the required photometric file and actual installation layout.
| Catalogue reference | Space-height ratio | Mounting height | MH wattage · catalogue guide |
|---|---|---|---|
| BC9306S-L30-60°×80° | 1.25 | 3–6 m | 70 W |
| BC9306S-L40-60°×80° | 1.25 | 3–6 m | 100 W |
| BC9306S-L50-60°×80° | 1.25 | 3–6 m | 100–150 W |
| BC9306S-L60-60°×80° | 1.25 | 5–8 m | 150 W |
| BC9306S-L80-60°×80° | 1.25 | 5–8 m | 175 W |
| BC9306S-L30-90°×110° | 1.75 | 3–6 m | 70 W |
| BC9306S-L40-90°×110° | 1.75 | 3–6 m | 100 W |
| BC9306S-L50-90°×110° | 1.75 | 3–6 m | 100–150 W |
| BC9306S-L60-90°×110° | 1.75 | 5–8 m | 150 W |
| BC9306S-L80-90°×110° | 1.75 | 5–8 m | 175 W |
| BC9306S-L30-200° | 1.75 | 3–6 m | 70 W |
| BC9306S-L40-200° | 1.75 | 3–6 m | 100 W |
| BC9306S-L50-200° | 1.75 | 3–6 m | 100–150 W |
| BC9306S-L60-200° | 1.75 | 4–8 m | 150 W |
| BC9306S-L80-200° | 1.75 | 4–8 m | 175 W |
| BC9306S-L25L-60°×80° | 1.25 | 3–6 m | 70 W |
| BC9306S-L40L-60°×80° | 1.25 | 3–6 m | 100 W |
| BC9306S-L60L-60°×80° | 1.25 | 5–8 m | 150 W |
| BC9306S-L25L-90°×110° | 1.75 | 3–6 m | 70 W |
| BC9306S-L40L-90°×110° | 1.75 | 3–6 m | 100 W |
| BC9306S-L60L-90°×110° | 1.75 | 5–8 m | 150 W |
| BC9306S-L25L-200° | 1.75 | 3–6 m | 70 W |
| BC9306S-L40L-200° | 1.75 | 3–6 m | 100 W |
| BC9306S-L60L-200° | 1.75 | 4–8 m | 150 W |
APPLICATION & SELECTION
Match the light to the site's area classification, operating conditions, mounting height and target illuminance.
Work areas on offshore oil and drilling platforms.
Operational and maintenance areas in oilfield and petroleum installations.
Work lighting in chemical facilities, selected to the area's classification and environment.
Industrial work areas where the site's hazardous area and lighting requirements call for this series.
The series is listed for gas Zone 1 and Zone 2, with gas marking Ex db eb IIC T6/T5/T4 Gb. It is also listed for dust Zone 21 and Zone 22, with dust marking Ex tb IIIC T80°C/T95°C/T130°C Db. Include the required temperature class and ambient temperature with your inquiry so the appropriate configuration can be specified.
The optic changes the listed luminous output. At 80 W, the 60° × 80° version is 8,800 lm, the 90° × 110° version is 8,400 lm, and the 200° version is 6,800 lm. Compare beam distribution and output together when selecting a light.
Dedicated low voltage models accept 18–43 VAC or 18–55 VDC. They are listed at 25, 40 and 60 W with 60° × 80°, 90° × 110° and 200° beam options. Use the full low voltage model reference, such as BC9306S-L40L-60°×80°, in your inquiry.
Send the model reference, quantity, supply voltage, CCT, CRI, mounting method and cable entry requirement. Add the site classification, required Ex marking and ambient temperature. For help with light selection, include mounting height, the area to be illuminated and the target illuminance. State whether optional P07 pole mounting accessories are required.
YOUR SELECTED CONFIGURATION
Send the model, quantity and project requirements to TORMIN. Include the hazardous-area classification and ambient temperature.
Continue with your selected reference and options. Add the area classification, ambient temperature and project requirements on the contact form.