BC9306S Explosion Proof LED Area Light — product image

HAZARDOUS AREA LIGHTING

BC9306S Explosion Proof LED Area Light

Bracket-mounted LED lighting with three standard beam distributions, 30–80 W AC models and dedicated 25 / 40 / 60 W low-voltage versions.

Power options
AC: 30–80 W; low voltage: 25 / 40 / 60 W
Beam options
60°×80° / 90°×110° / 200°
Standard input
90–264 VAC
Ingress protection
IP66

BUILT AROUND YOUR INSTALLATION

Bracket-mounted lighting for industrial work areas

The BC9306S combines an aluminum housing, 304 stainless steel bracket and exposed fasteners, and an independent wiring chamber. Three standard distributions cover different lighting layouts. Start with your electrical supply, then compare power and beam options against the required coverage and illuminance.

Beam-specific performance

Compare 60° × 80°, 90° × 110° and 200° distributions. Luminous output is listed for each power and beam combination, so you can select against the actual configuration.

AC and low voltage choices

Standard versions use 90–264 VAC. Dedicated low voltage models use 18–43 VAC or 18–55 VDC and are listed at 25, 40 and 60 W.

Industrial housing and hardware

An aluminum housing with an anti-corrosion surface coating, 304 stainless steel bracket and exposed fasteners, and IP66 protection supports demanding industrial installations.

Flexible installation

Choose seat, ceiling, side wall or pole mounting. The separate wiring chamber provides access for installation, and optional pole mounting accessories are listed under P07.

POWER · OPTICS · INSTALLATION

Choose your configuration

Select a listed supply, power and beam combination. Add the installation details to your enquiry.

Compare all 24 configurations ↓

Ra70 is standard; Ra80 can be requested. CCT, CRI and installation choices accompany the catalogue reference and are confirmed with your quotation.

Selected catalogue reference
BC9306S-L50-90°×110°
5,600 lm
Catalogue reference output
90–264 VAC

Confirm output for optional CCT / CRI. The 18° spotlight is a separate version.

Enquire about this configuration

1. Match the supply

Choose standard AC for 90–264 VAC, or a dedicated low voltage model for 18–43 VAC / 18–55 VDC.

2. Compare the beam

Use 60° × 80° or 90° × 110° for directional coverage, or 200° for a broad distribution. Confirm the final layout against mounting height, target illuminance and photometric data.

3. Select power and output

Read the luminous flux for the selected beam and power together. At 80 W, the standard versions provide 8,800 lm at 60° × 80°, 8,400 lm at 90° × 110°, or 6,800 lm at 200°.

4. Complete the installation details

Specify mounting, cable entry, CCT, CRI, site classification and ambient temperature. Standard CCT is 5000 K, with 3000 K and 4000 K options; standard CRI is Ra70, with Ra80 available as an option.

CATALOGUE CONFIGURATIONS

Compare power and light distribution

Read the output for each beam and power together. The low-voltage models have their own references with an additional L suffix.

Original specification pages ↗

Standard AC

90–264 VAC, 50/60 Hz
15 catalogue configurations · 90–264 VAC, 50/60 Hz
Catalogue referencePowerDistributionLuminous fluxSelect
BC9306S-L30-60°×80°30 W60° × 80°3,500 lm
BC9306S-L40-60°×80°40 W60° × 80°4,600 lm
BC9306S-L50-60°×80°50 W60° × 80°5,600 lm
BC9306S-L60-60°×80°60 W60° × 80°6,900 lm
BC9306S-L80-60°×80°80 W60° × 80°8,800 lm
BC9306S-L30-90°×110°30 W90° × 110°3,400 lm
BC9306S-L40-90°×110°40 W90° × 110°4,400 lm
BC9306S-L50-90°×110°50 W90° × 110°5,600 lm
BC9306S-L60-90°×110°60 W90° × 110°6,700 lm
BC9306S-L80-90°×110°80 W90° × 110°8,400 lm
BC9306S-L30-200°30 W200°2,800 lm
BC9306S-L40-200°40 W200°3,700 lm
BC9306S-L50-200°50 W200°4,500 lm
BC9306S-L60-200°60 W200°5,400 lm
BC9306S-L80-200°80 W200°6,800 lm

Low voltage AC/DC

18–43 VAC / 18–55 VDC
9 catalogue configurations · 18–43 VAC / 18–55 VDC
Catalogue referencePowerDistributionLuminous fluxSelect
BC9306S-L25L-60°×80°25 W60° × 80°2,900 lm
BC9306S-L40L-60°×80°40 W60° × 80°4,600 lm
BC9306S-L60L-60°×80°60 W60° × 80°6,900 lm
BC9306S-L25L-90°×110°25 W90° × 110°2,700 lm
BC9306S-L40L-90°×110°40 W90° × 110°4,400 lm
BC9306S-L60L-90°×110°60 W90° × 110°6,700 lm
BC9306S-L25L-200°25 W200°2,400 lm
BC9306S-L40L-200°40 W200°3,700 lm
BC9306S-L60L-200°60 W200°5,400 lm

All values above are catalogue figures for the listed references. Confirm photometric performance for optional CCT / CRI and the final installation layout. For the separate 18° version, see BC9306S Spotlight.

TECHNICAL DETAILS

Electrical, optical and mechanical specifications

Electrical & optical

Light sourceLED
Standard AC supply90–264 VAC · 50 / 60 Hz
Low-voltage supply18–43 VAC / 18–55 VDC
AC power options30 / 40 / 50 / 60 / 80 W
Low-voltage power25 / 40 / 60 W
Beam distributions60° × 80° / 90° × 110° / 200°
Optional control / lensesThe catalogue lists 1–10 VDC, PWM, carrier and DALI dimming, and custom 40°, 60°, 80° and 100° lenses. Request these options with the enquiry; availability, output and applicable certification must be confirmed for the exact configuration.
Colour temperature5000 K standard; 3000 / 4000 K optional
Colour renderingRa70 standard; Ra80 optional
Catalogue life figure50,000 hours

Housing & installation

HousingAluminium, anti-corrosion surface coating
Bracket / fasteners304 stainless steel
Ingress protectionIP66
Catalogue ambient optionsMinimum −50 °C; upper limits +40 °C or +55 °C, depending on the configuration. Confirm the exact reference, temperature class and permitted ambient range in its applicable model documents.
Dimensions245 × 260 × 270 mm
Net weight4.9 kg
Cable entry optionsM20 × 1.5 / NPT ½″
Terminal cross-sectionMulti-core ≤2.5 mm²; single-core ≤4 mm²
MountingSeat / ceiling / side wall / pole
Wiring accessIndependent wiring chamber
ATEX certificate:EPT 16 ATEX 2484 X
Archived copy on this site; confirm current status before specification.
IECEx certificate:IECEx CML 24.0116X
Archived copy on this site; confirm current status before specification.

BC9306S ATEX & IECEx certificates

DIMENSIONS & ACCESSORIES

Fit the light to the installation

Standard and low-voltage versions use the dimensions shown here. Review the drawing and specify the mounting arrangement with your enquiry.

Original BC9306S dimension drawing showing seat, ceiling, side wall and pole mounting and the optional P07 kit
Original TORMIN drawing · dimensions in mm · catalogue page 042

Four mounting arrangements

  • Seat mounting
  • Ceiling mounting
  • Side wall mounting
  • Pole mounting

OPTIONAL ACCESSORY KIT

P07 · Pole mounting accessories

Request P07 when specifying a pole installation. The catalogue lists the following items separately from the luminaire.

M20 waterproof plug1 pc · Ø8–12 mm cable
Vertical mounting pole1 pc · Ø40–50 mm pole

Confirm accessory inclusion in the final quotation.

For the 18° spotlight, use its separate 291 × 260 × 270 mm drawing.

Photometric curves

Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.

BC9306S · model and light-distribution reference · catalogue PDF page 45
BC9306S · model and light-distribution reference · catalogue PDF page 45 · Open full-size image ↗

MODEL DOCUMENTS

Review the specification and certification scope

Use the current applicable certificate and its conditions to confirm the exact model, temperature class and permitted ambient range.

Gas areas · catalogueZone 1 / 2 · IIA, IIB, IIC
Gas Ex markingEx db eb IIC T6/T5/T4 Gb
Dust areas · catalogueZone 21 / 22
Dust Ex markingEx tb IIIC T80°C/T95°C/T130°C Db

Check the exact configuration

Temperature classes and ambient limits vary by configuration. The website's family certificate copies are identified as archived, with current status unverified. Ask TORMIN for the applicable documentation for the selected reference.

Visit the certification library ↗

BC9306S datasheet · 2025 catalogue

Standard AC and low-voltage configurations, technical data and mounting drawing. Original catalogue pages 040–042.

Download PDF · 3 pages ↗

Original mounting drawing

Seat, ceiling, side wall and pole arrangements, plus the P07 accessory listing.

Open full-size drawing ↗
Archived copy · current status unverified

ATEX · EPT 16 ATEX 2484 X

BC9306 / BC9307 family document. Check the original schedule for exact variant coverage and special conditions.

Review original ATEX PDF ↗
Archived copy · current status unverified

IECEx · IECEx CML 24.0116X

BC9306 / BC9307 family document. Check the original schedule for exact variant coverage and special conditions.

Review original IECEx PDF ↗

Need IES / LDT files or installation instructions? Include the selected reference with your request.

Catalogue installation guidance

Original catalogue page 041 lists the following spacing and mounting-height guidance, together with indicative metal-halide (MH) replacement wattages. Use these values for initial selection; confirm illuminance, coverage and replacement suitability using the required photometric file and actual installation layout.

BC9306S · catalogue spacing, mounting height and MH guide
Catalogue referenceSpace-height ratioMounting heightMH wattage · catalogue guide
BC9306S-L30-60°×80°1.253–6 m70 W
BC9306S-L40-60°×80°1.253–6 m100 W
BC9306S-L50-60°×80°1.253–6 m100–150 W
BC9306S-L60-60°×80°1.255–8 m150 W
BC9306S-L80-60°×80°1.255–8 m175 W
BC9306S-L30-90°×110°1.753–6 m70 W
BC9306S-L40-90°×110°1.753–6 m100 W
BC9306S-L50-90°×110°1.753–6 m100–150 W
BC9306S-L60-90°×110°1.755–8 m150 W
BC9306S-L80-90°×110°1.755–8 m175 W
BC9306S-L30-200°1.753–6 m70 W
BC9306S-L40-200°1.753–6 m100 W
BC9306S-L50-200°1.753–6 m100–150 W
BC9306S-L60-200°1.754–8 m150 W
BC9306S-L80-200°1.754–8 m175 W
BC9306S-L25L-60°×80°1.253–6 m70 W
BC9306S-L40L-60°×80°1.253–6 m100 W
BC9306S-L60L-60°×80°1.255–8 m150 W
BC9306S-L25L-90°×110°1.753–6 m70 W
BC9306S-L40L-90°×110°1.753–6 m100 W
BC9306S-L60L-90°×110°1.755–8 m150 W
BC9306S-L25L-200°1.753–6 m70 W
BC9306S-L40L-200°1.753–6 m100 W
BC9306S-L60L-200°1.754–8 m150 W

APPLICATION & SELECTION

For industrial work areas

Match the light to the site's area classification, operating conditions, mounting height and target illuminance.

Offshore platforms

Work areas on offshore oil and drilling platforms.

Oilfield and petroleum facilities

Operational and maintenance areas in oilfield and petroleum installations.

Chemical processing

Work lighting in chemical facilities, selected to the area's classification and environment.

Steel industry

Industrial work areas where the site's hazardous area and lighting requirements call for this series.

Can I specify the BC9306S for Zone 1?

The series is listed for gas Zone 1 and Zone 2, with gas marking Ex db eb IIC T6/T5/T4 Gb. It is also listed for dust Zone 21 and Zone 22, with dust marking Ex tb IIIC T80°C/T95°C/T130°C Db. Include the required temperature class and ambient temperature with your inquiry so the appropriate configuration can be specified.

Why do 80 W configurations have different lumen values?

The optic changes the listed luminous output. At 80 W, the 60° × 80° version is 8,800 lm, the 90° × 110° version is 8,400 lm, and the 200° version is 6,800 lm. Compare beam distribution and output together when selecting a light.

Which models can operate from a low voltage supply?

Dedicated low voltage models accept 18–43 VAC or 18–55 VDC. They are listed at 25, 40 and 60 W with 60° × 80°, 90° × 110° and 200° beam options. Use the full low voltage model reference, such as BC9306S-L40L-60°×80°, in your inquiry.

What should I provide for an accurate quotation?

Send the model reference, quantity, supply voltage, CCT, CRI, mounting method and cable entry requirement. Add the site classification, required Ex marking and ambient temperature. For help with light selection, include mounting height, the area to be illuminated and the target illuminance. State whether optional P07 pole mounting accessories are required.

YOUR SELECTED CONFIGURATION

Request a BC9306S quotation

Send the model, quantity and project requirements to TORMIN. Include the hazardous-area classification and ambient temperature.

BC9306S-L50-90°×110°
90–264 VAC · 5000 K · Seat mounting · M20 × 1.5
Change configuration ↑
Continue to TORMIN enquiry

Continue with your selected reference and options. Add the area classification, ambient temperature and project requirements on the contact form.

Tell us what you need.

Fields marked * are required.

Your details will be used to respond to this enquiry.