Vertical pole attachment
The optional vertical mounting pole is shown for installation on a Ø40–50 mm supporting pole.
HAZARDOUS AREA LIGHTING
The BC9700 pole-mounted arrangement uses a separate vertical attachment for fixed lighting around industrial equipment and platforms. The catalogue shows how the bracket assembly connects to a supporting pole.
The optional vertical mounting pole is shown for installation on a Ø40–50 mm supporting pole.
The bracket includes an angle-locking device to set the lighting direction.
The aluminium housing uses 304 stainless steel exposed fasteners and a protective surface treatment.
The source describes replacement of the driver assembly without welding.
Select a listed catalogue reference and add your installation requirements.
Additional installation and specification requirements are confirmed with your quotation.
| Model | Supply | Power | Beam distribution | Catalogue mounting height (m) | Space-height ratio | Catalogue luminous flux | Select |
|---|---|---|---|---|---|---|---|
| BC9700-L50-80° | 90–305 VAC | 50 W | 80° | 8–12 m | 1.35 | 6,000 lm | |
| BC9700-L60-80° | 90–305 VAC | 60 W | 80° | 8–12 m | 1.35 | 7,200 lm | |
| BC9700-L80-80° | 90–305 VAC | 80 W | 80° | 8–12 m | 1.35 | 9,600 lm | |
| BC9700-L100-80° | 90–305 VAC | 100 W | 80° | 8–12 m | 1.35 | 12,000 lm | |
| BC9700-L120-80° | 90–305 VAC | 120 W | 80° | 8–12 m | 1.35 | 14,400 lm | |
| BC9700-L150-80° | 90–305 VAC | 150 W | 80° | 10–15 m | 1.35 | 18,000 lm | |
| BC9700-L200-80° | 90–305 VAC | 200 W | 80° | 10–15 m | 1.35 | 24,000 lm | |
| BC9700-L50-100° | 90–305 VAC | 50 W | 100° | 8–12 m | 1.4 | 6,000 lm | |
| BC9700-L60-100° | 90–305 VAC | 60 W | 100° | 8–12 m | 1.4 | 7,200 lm | |
| BC9700-L80-100° | 90–305 VAC | 80 W | 100° | 8–12 m | 1.4 | 9,600 lm | |
| BC9700-L100-100° | 90–305 VAC | 100 W | 100° | 8–12 m | 1.4 | 12,000 lm | |
| BC9700-L120-100° | 90–305 VAC | 120 W | 100° | 8–12 m | 1.4 | 14,400 lm | |
| BC9700-L150-100° | 90–305 VAC | 150 W | 100° | 10–15 m | 1.4 | 18,000 lm | |
| BC9700-L200-100° | 90–305 VAC | 200 W | 100° | 10–15 m | 1.4 | 24,000 lm | |
| BC9700-L50-60°×80° | 90–305 VAC | 50 W | 60°×80° | 8–12 m | 1.25 | 6,000 lm | |
| BC9700-L60-60°×80° | 90–305 VAC | 60 W | 60°×80° | 8–12 m | 1.25 | 7,200 lm | |
| BC9700-L80-60°×80° | 90–305 VAC | 80 W | 60°×80° | 8–12 m | 1.25 | 9,600 lm | |
| BC9700-L100-60°×80° | 90–305 VAC | 100 W | 60°×80° | 8–12 m | 1.25 | 12,000 lm | |
| BC9700-L120-60°×80° | 90–305 VAC | 120 W | 60°×80° | 8–12 m | 1.25 | 14,400 lm | |
| BC9700-L150-60°×80° | 90–305 VAC | 150 W | 60°×80° | 10–15 m | 1.25 | 18,000 lm | |
| BC9700-L200-60°×80° | 90–305 VAC | 200 W | 60°×80° | 10–15 m | 1.25 | 24,000 lm | |
| BC9700-L50-90°×110° | 90–305 VAC | 50 W | 90°×110° | 8–12 m | 1.75 | 6,000 lm | |
| BC9700-L60-90°×110° | 90–305 VAC | 60 W | 90°×110° | 8–12 m | 1.75 | 7,200 lm | |
| BC9700-L80-90°×110° | 90–305 VAC | 80 W | 90°×110° | 8–12 m | 1.75 | 9,600 lm | |
| BC9700-L100-90°×110° | 90–305 VAC | 100 W | 90°×110° | 8–12 m | 1.75 | 12,000 lm | |
| BC9700-L120-90°×110° | 90–305 VAC | 120 W | 90°×110° | 8–12 m | 1.75 | 14,400 lm | |
| BC9700-L150-90°×110° | 90–305 VAC | 150 W | 90°×110° | 10–15 m | 1.75 | 18,000 lm | |
| BC9700-L200-90°×110° | 90–305 VAC | 200 W | 90°×110° | 10–15 m | 1.75 | 24,000 lm |
| Input voltage (V) | 90~305VAC |
|---|---|
| Rated frequency | 50Hz / 60Hz |
| Light source | LED |
| Life time (h) | 50,000 |
| CRI (Ra) | 70 (80 optional) |
| CCT | 5000K(3000K/4000K optional) |
| Printed Ex marking | Ex db IIC T5/T4/T3 Gb; Ex tb IIIC T95°C/T130°C/T195°C Db |
| Ambient options printed in catalogue | −40 to +40 / +55 °C; exact variant and temperature class to be confirmed |
| Catalogue application areas | Gas Zones 1 and 2; dust Zones 21 and 22. Confirm the applicable model marking and installation conditions. |
| Cable Entry | M20×1.5, M25×1.5, G3/4", NPT1/2", NPT3/4" |
|---|---|
| Dimension (mm) | 300×202×332 |
| Net weight (kg) | 6.3 |
| Ingress protection | IP66 |
| ATEX certificate: | EPT 16 ATEX 2483 X Archived copy on this site; confirm current status before specification. |
|---|---|
| IECEx certificate: | IECEx CML 24.0118X Archived copy on this site; confirm current status before specification. |
Original catalogue drawings. Dimensions are in millimetres unless stated otherwise. Open an image to inspect the full-size drawing.
| Reference | Space-height ratio | Mounting height | Equivalent metal-halide wattage (catalogue) | PDF page |
|---|---|---|---|---|
| BC9700-L50-80° | 1.35 | 8–12 m | 150 W | 71 |
| BC9700-L60-80° | 1.35 | 8–12 m | 150 W | 71 |
| BC9700-L80-80° | 1.35 | 8–12 m | 175 W | 71 |
| BC9700-L100-80° | 1.35 | 8–12 m | 250 W | 71 |
| BC9700-L120-80° | 1.35 | 8–12 m | >250 W | 71 |
| BC9700-L150-80° | 1.35 | 10–15 m | 400 W | 71 |
| BC9700-L200-80° | 1.35 | 10–15 m | >400 W | 71 |
| BC9700-L50-100° | 1.4 | 8–12 m | 150 W | 72 |
| BC9700-L60-100° | 1.4 | 8–12 m | 150 W | 72 |
| BC9700-L80-100° | 1.4 | 8–12 m | 175 W | 72 |
| BC9700-L100-100° | 1.4 | 8–12 m | 250 W | 72 |
| BC9700-L120-100° | 1.4 | 8–12 m | >250 W | 72 |
| BC9700-L150-100° | 1.4 | 10–15 m | 400 W | 72 |
| BC9700-L200-100° | 1.4 | 10–15 m | >400 W | 72 |
| BC9700-L50-60°×80° | 1.25 | 8–12 m | 150 W | 72 |
| BC9700-L60-60°×80° | 1.25 | 8–12 m | 150 W | 72 |
| BC9700-L80-60°×80° | 1.25 | 8–12 m | 175 W | 72 |
| BC9700-L100-60°×80° | 1.25 | 8–12 m | 250 W | 72 |
| BC9700-L120-60°×80° | 1.25 | 8–12 m | >250 W | 72 |
| BC9700-L150-60°×80° | 1.25 | 10–15 m | 400 W | 72 |
| BC9700-L200-60°×80° | 1.25 | 10–15 m | >400 W | 72 |
| BC9700-L50-90°×110° | 1.75 | 8–12 m | 150 W | 72 |
| BC9700-L60-90°×110° | 1.75 | 8–12 m | 150 W | 72 |
| BC9700-L80-90°×110° | 1.75 | 8–12 m | 175 W | 72 |
| BC9700-L100-90°×110° | 1.75 | 8–12 m | 250 W | 72 |
| BC9700-L120-90°×110° | 1.75 | 8–12 m | >250 W | 72 |
| BC9700-L150-90°×110° | 1.75 | 10–15 m | 400 W | 72 |
| BC9700-L200-90°×110° | 1.75 | 10–15 m | >400 W | 72 |
Original catalogue curves. Read each curve with its listed model, beam and supply. Open an image to inspect the full-size plot.


Original catalogue extract · 2 pages · PDF · 504 KB
View documentOriginal catalogue pages 71, 72